Engineering Method for Thermal Calculation of Magnetizing Windings of Air-Cooled Betatrons
Abstract Generated abstract
This paper presents an engineering method for calculating the thermal state of air-cooled magnetizing windings in betatrons when heat generation along a vertical row of winding bars varies approximately linearly with height. Using heat-transfer relations for air supplied either from below or from above, the authors derive series expressions, simplified one-term formulas, and equations for locating the maximum surface temperature. The work supplies tabulated roots of the required transcendental equation, a nomographic aid for evaluating a coefficient in the formulas, and a step-by-step calculation procedure. The method is intended to determine the air velocity and total airflow needed so that the maximum winding temperature does not exceed the permissible value.
Full Text
ENGINEERING METHOD FOR THERMAL CALCULATION OF MAGNETIZING WINDINGS OF BETATRONS WITH AIR COOLING
G. F. Shilin, G. I. Fuks
A reliable selection and calculation of the cooling system for the magnetizing windings of betatrons requires knowledge of the temperature distribution over the surface of the vertical rows of winding bars and of the law of heat generation within its volume.
Fig. 1. On the engineering method for thermal calculation of the magnetizing winding of a betatron.
If the heat generation is constant over the volume of a vertical row of bars, then the law of temperature distribution over its height can be found by the method given in [1]. However, our experiments showed that usu-
but the heat release over the height of a vertical row of busbars depends linearly on the vertical coordinate, that is,
\[ q_0=L+Mx,\ \mathrm{W/m^3}, \tag{1} \]
where \(x\) is the vertical coordinate of the winding in m (Fig. 1).
Consequently [1], using this relation, one can determine the law of temperature variation along the wall of the vertical rows of winding busbars in various cases.
a) Air is supplied into the winding slots from below at \(X=0\) (Fig. 1). Then
\[ t_{\mathrm{st}}(X)=t_{\mathrm{in}}+\frac{2U}{\mathrm{Pe}}\mathrm{Nu}\,\frac{a}{s} \sum_{m=1}^{\infty} A_m \left(\sin\mu_m X-\frac{\mathrm{Bi}}{\mu_m}\cos\mu_m X+\frac{\mathrm{Bi}}{\mu_m}\right)+ \tag{2} \]
\[ +\sum_{m=1}^{\infty} A_m\left(\mu_m\cos\mu_m X+\mathrm{Bi}\sin\mu_m X\right). \]
b) Air is supplied into the winding slots from above at \(X=1\). Then
\[ t_{\mathrm{st}}(X)=t_{\mathrm{in}}-\frac{2U}{\mathrm{Pe}}\mathrm{Nu}\cdot\frac{a}{s} \sum_{m=1}^{\infty} A_m\left[(\sin\mu_m X-\sin\mu_m)- \right. \tag{3} \]
\[ \left. -\frac{\mathrm{Bi}}{\mu_m}(\cos\mu_m X-\cos\mu_m)\right] +\sum_{m=1}^{\infty} A_m\left(\mu_m\cos\mu_m X+\mathrm{Bi}\cdot\cos\mu_m X\right). \]
In formulas (2) and (3):
\[ A_m= \frac{ F(\mu_m)\cdot \operatorname{sh}\dfrac{\mu_m}{\eta} }{ \mu_m\cdot D(\mu_m) \left[ \mu_m \operatorname{sh}\dfrac{\mu_m}{\eta} +\mathrm{Bi}\operatorname{ch}\dfrac{\mu_m}{\eta} \right] }; \tag{4} \]
\[ D(\mu_m)=\frac{1}{2\mu_m} \left\{ \mu_m^2(\mu_m+0.5\sin 2\mu_m) +\mathrm{Bi}^2(\mu_m-0.5\sin 2\mu_m) +2\mu_m\cdot\mathrm{Bi}\cdot\sin^3\mu_m \right\}; \]
\[ F(\mu_m)= \frac{\beta}{\mu_m} \left[\mu_m\cdot\sin\mu_m+\mathrm{Bi}(1-\cos\mu_m)\right]+ \]
\[ +\frac{\gamma}{\mu_m^2} \left[\mu_m\cdot\cos\mu_m(1-\mathrm{Bi}) +\sin\mu_m(\mathrm{Bi}+\mu_m^2)-\mu_m\right]; \]
\[ \beta=4\,\frac{L}{\lambda_{\mathrm{eq}}}\cdot a^2; \qquad \gamma=8\,\frac{M}{\lambda_{\mathrm{eq}}}\cdot a^3; \qquad \eta=\frac{a}{b}; \]
\[ X=\frac{x}{2a}; \qquad \mathrm{Bi}=\frac{\alpha\cdot 2a}{\lambda_{\mathrm{eq}}}; \qquad \mathrm{Pe}=\frac{W\cdot 2s}{a^*}; \qquad \mathrm{Nu}=\frac{\alpha\cdot 2s}{\lambda_{\mathrm{air}}}; \]
\(W\) is the air velocity in the cooling slots of the winding, in m/s;
\(\alpha\) is the heat-transfer coefficient in the winding slot to air with temperature \(t_{\mathrm{in}}\), in \(\mathrm{W/m^2\cdot deg}\);
\(s\) is the width of the cooling slot, in m (Fig. 1);
\(a^*\) and \(\lambda_{\mathrm{air}}\) are the thermal diffusivity coefficient and thermal conductivity of air;
\(\lambda_{\mathrm{eq}}\) is the equivalent thermal-conductivity coefficient of the winding, in \(\mathrm{W/(m\cdot deg)}\);
Table 1
Roots of the equation
\[ \operatorname{tg}\mu_m=\frac{2\mathrm{Bi}\cdot\mu_m}{\mu_m^{2}-\mathrm{Bi}^{2}} \]
| No. | Bi | \(\mu_1\) | \(\mu_2\) | \(\mu_3\) |
|---|---|---|---|---|
| 1 | 0,005 | 0,099947 | 3,1448 | 6,2848 |
| 2 | 0,01 | 0,13970 | 3,14799 | 6,28637 |
| 3 | 0,02 | 0,19966 | 3,15420 | 6,2896 |
| 4 | 0,03 | 0,24433 | 3,1605 | 6,2926 |
| 5 | 0,04 | 0,28190 | 3,1668 | 6,2956 |
| 6 | 0,05 | 0,31491 | 3,1731 | 6,29905 |
| 7 | 0,06 | 0,34468 | 3,1793 | 6,3020 |
| 8 | 0,07 | 0,37200 | 3,1852 | 0,3053 |
| 9 | 0,08 | 0,39733 | 3,1914 | 6,3084 |
| 10 | 0,09 | 0,42111 | 3,1979 | 6,3114 |
| 11 | 0,10 | 0,4353 | 3,20400 | 6,31485 |
| 12 | 0,20 | 0,62210 | 3,2638 | 6,3459 |
| 13 | 0,30 | 0,7574 | 3,32173 | 6,37710 |
| 14 | 0,40 | 0,86567 | 3,3773 | 6,4076 |
| 15 | 0,50 | 0,96020 | 3,43101 | 6,43320 |
| 16 | 0,60 | 1,0433 | 3,4827 | 6,4680 |
| 17 | 0,70 | 1,1183 | 3,5327 | 6,4977 |
| 18 | 0,80 | 1,1864 | 3,5810 | 6,5271 |
| 19 | 0,90 | 1,2488 | 3,6280 | 6,5559 |
| 20 | 1,0 | 1,3052 | 3,67919 | 6,58462 |
| 21 | 1,1 | 1,3600 | 3,7168 | 0,6127 |
| 22 | 1,2 | 1,4100 | 3,7592 | 6,6406 |
| 23 | 1,3 | 1,4568 | 3,8007 | 6,6580 |
| 24 | 1,4 | 1,5009 | 3,8407 | 6,6954 |
| 25 | 1,6 | 1,5820 | 3,9170 | 6,7484 |
| 26 | 1,8 | 1,6545 | 3,9892 | 6,8005 |
| 27 | 2,0 | ,7206 | 4,05740 | 6,85120 |
| 28 | 2,2 | 1,7806 | 4,1218 | 6,9003 |
| 29 | 2,4 | 1,856 | 4,1833 | 6,9483 |
| 30 | 2,6 | 1,8862 | 4,2415 | 6,9946 |
| 31 | 2,8 | 1,9330 | 4,2965 | 7,0400 |
| 32 | 3,0 | 1,9763 | 4,3492 | 7,0842 |
| 33 | 3,5 | 2,0723 | 4,4699 | 7,1892 |
| 34 | 4,0 | 2,1536 | 4,5777 | 7,2868 |
| 35 | 4,5 | 2,2236 | 4,6742 | 7,3783 |
| 36 | 5,0 | 2,28445 | 4,76129 | 7,46367 |
| 37 | 5,5 | 2,3377 | 4,8395 | 7,5430 |
| 38 | 6,0 | 2,3848 | 4,9112 | 7,6174 |
Continuation of Table 1
| $\mathrm{Bi}$ | $\mu_1$ | $\mu_2$ | $\mu_3$ | |
|---|---|---|---|---|
| 39 | 6,5 | 2,4268 | 4,9762 | 7,6868 |
| 40 | 7,0 | 2,4645 | 5,0357 | 7,7518 |
| 41 | 7,5 | 2,4983 | 5,0903 | 7,8127 |
| 42 | 8,0 | 2,5289 | 5,1406 | 7,8715 |
| 43 | 8,5 | 2,5571 | 5,1872 | 7,9225 |
| 44 | 9,0 | 2,5824 | 5,2300 | 7,9745 |
| 45 | 9,5 | 2,6059 | 5,2700 | 8,0221 |
| 46 | 10 | 2,62768 | 5,30732 | 8,06713 |
| 47 | 20 | 2,8577 | 5,7253 | 8,6115 |
| 48 | 30 | 2,9456 | 5,8950 | 8,8509 |
| 49 | 40 | 2,9921 | 5,9859 | 8,9827 |
| 50 | 50 | 3,02090 | 6,04265 | 9,06626 |
| 51 | 60 | 3,0402 | 6,0809 | 9,1230 |
| 52 | 70 | 3,0542 | 6,1087 | 9,1642 |
| 53 | 80 | 3,0648 | 6,1302 | 9,1957 |
| 54 | 90 | 3,0731 | 6,1464 | 9,207 |
| 55 | 100 | 3,0800 | 6,16014 | 9,24480 |
| 56 | $\infty$ | 3,1416 | 6,2832 | 9,4248 |
$U$ is the perimeter of the flow cross section of the winding cooling slot, in m;
$\mu_m$ are the roots of the equation
\[ \operatorname{tg}\mu_m=\frac{2\mathrm{Bi}\cdot \mu_m}{\mu_m^2-\mathrm{Bi}^2}. \]
The first three roots of this equation, found on the Promin electronic digital computer, are presented in Table 1.
Relations (2) and (3) can be simplified if it is taken into account that the series in them converge rapidly. In engineering calculations, these dependences may be used with one term of the series, $m=1$. Then:
a) air is supplied into the winding slots from below at $X=0$ (Fig. 1),
\[ t_{\mathrm{st}}(X)=t_{\mathrm{in}}+\frac{2U}{\mathrm{Pe}}\cdot \mathrm{Nu}\,\frac{a}{s}\,A_1 \left(\sin\mu_1 X-\frac{\mathrm{Bi}}{\mu_1}\cos\mu_1 X+\frac{\mathrm{Bi}}{\mu_1}\right)+ \tag{5} \]
\[ +\,A_1(\mu_1\cos\mu_1 X+\mathrm{Bi}\sin\mu_1 X), \]
where $A_1$ is calculated from (4), with $m=1$.
The coordinate of the maximum temperature is found from the expression:
\[ X_{\max}=\frac{1}{\mu_1}\operatorname{arctg} \left[ \frac{-\mu_1\left(\mathrm{Bi}-\dfrac{2U}{\mathrm{Pe}}\mathrm{Nu}\,\dfrac{a}{s}\right)} {\mathrm{Bi}\left(\dfrac{\mu_1^2}{\mathrm{Bi}}+\dfrac{2U}{\mathrm{Pe}}\mathrm{Nu}\,\dfrac{a}{s}\right)} \right]; \tag{6} \]
b) air is supplied into the winding slots from above at $X=1$ (Fig. 1),
\[
t_{\mathrm{st}}(X)=t_{\mathrm{in}}-\frac{2U}{\mathrm{Pe}}\,\mathrm{Nu}\cdot \frac{a}{s}\,A_1\left[(\sin \mu_1X-\sin \mu_1)-\frac{\mathrm{Bi}}{\mu_1}(\cos \mu_1X-\cos \mu_1)\right]+
\]
\[
+\,A_1(\mu_1\cos \mu_1X+\mathrm{Bi}\cdot \sin \mu_1X).
\tag{7}
\]
The coordinate of the maximum temperature is determined from the relation:
\[ X_{\max}=\frac{1}{\mu_1}\operatorname{arctg} \left[ \frac{\mu_1\left(\mathrm{Bi}+\dfrac{2U}{\mathrm{Pe}}\,\mathrm{Nu}\cdot \dfrac{a}{s}\right)} {\mathrm{Bi}\left(\dfrac{\mu_1^2}{\mathrm{Bi}}-\dfrac{2U}{\mathrm{Pe}}\cdot \mathrm{Nu}\cdot \dfrac{a}{s}\right)} \right]. \tag{8} \]
For calculating \(A_1\) from (4), a nomogram has been constructed, which significantly reduces the labor of computational operations (Fig. 2).
Fig. 2. Nomogram for calculating the quantity \(A_1\) by formula (4).
The thermal calculation of the magnetizing winding of a betatron, based on the use of relations (5)—(8), must proceed according to the electro-
Table 2
Engineering procedure for the thermal calculation of the magnetizing winding of a betatron
| No. | Quantity | Designation | Calculated relations | Dimension | Note |
|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 6 |
| Data for calculation | |||||
| 1 | Type of betatron | — | — | — | |
| 2 | Height of the investigated vertical row of coils | \(2a\) | Fig. 1 | m | Thermal calculation should be performed for the 1st and 2nd rows, counting from the pole, which are more heavily loaded thermally |
| 3 | Width of the vertical row of coils | \(4b\) | Fig. 1 | m | |
| 4 | Magnetizing force of the secondary winding | \(I_2 w_2\) | — | Necessary for electrical modeling of the betatron field distribution in order to estimate the heat generation in the rows of buses | |
| 5 | Cross section of the winding bus | \(k \times l'\) | — | \(\mathrm{mm}^2\) | — |
| 6 | Resistance of the secondary winding | \(R\) | — | ohm | |
| 7 | Magnetizing current | \(I_2\) | — | A | |
| 8 | Heat losses in the copper of the magnetizing winding | \(Q\) | \(I_2^{2}R\) | W |
Continuation of Table 2
| 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|
| 9 | Volume of the magnetizing winding | \(V\) | \(2(2\pi\sum_{i=1}^{n} R_i\cdot 4b\cdot 2a)\) | \(\mathrm{m}^3\) | Fig. 1 |
| 10 | Heat generation in the magnetizing winding | \(q_{v}^{\mathrm{act}}\) | \(q_{v}^{\mathrm{act}}=\dfrac{Q}{V}\) | \(\mathrm{W}/\mathrm{m}^3\) | It is necessary to find the heat generation from eddy currents by [2] |
| 11 | Air temperature at entry into the winding cooling cell | \(t_{\mathrm{in}}\) | — | °C | |
| 12 | Permissible heating temperature of the winding | \(t_{\mathrm{dop}}\) | — | °C | |
| 13 | Width of cooling slots | \(s\) | — | m | Fig. 1 |
| 14 | Heat release in the volume of a vertical wedge from eddy currents and from active losses in the winding copper [2], per 1 m of the winding | \(q_{0}\) | \(q_{0}=L+M\cdot x\) | \(\mathrm{W}/\mathrm{m}^3\) | \(x\)—in m |
| 15 | Direction of air motion in the slots | From top to bottom or from bottom to top | Fig. 1 | ||
| 16 | Equivalent coefficient of thermal conductivity of the winding | \(\lambda_{\mathrm{eqv}}\) | \(\lambda_{\mathrm{eqv}}=\lambda_{0}+b\cdot t_{0}\) | \(\mathrm{W}/\mathrm{m}\cdot{}^\circ\mathrm{C}\) | Found from the experiment for a 10×3.25 mm busbar: 1) winding cell—two layers of glass tape (GOST [5]), impregnation—bakelite lacquer; \(\lambda_{\mathrm{eqv}}=2.523+2.03\cdot10^{-4}\,t\ \mathrm{W}/\mathrm{m}/^\circ\mathrm{C};\) 2) cell as above, impregnation—lacquer No. 447 GOST 6244-52; \(\lambda_{\mathrm{eqv}}=1.452+9.995\cdot10^{-4}\,t\ \mathrm{W}/\mathrm{m}/^\circ\mathrm{C}\). |
Continuation of Table 2
| No. | Quantity | Symbol | Formula | Unit | Notes |
|---|---|---|---|---|---|
| 17 | Total area of the flow cross-section of all cooling channels of the two parts of the winding | $\sum_i S_i$ | $\mathrm{m^2}$ | Fig. 1 | |
| Thermal calculation of the betatron magnetizing winding | |||||
| 1 | Air velocity in the cooling channels of the winding | $W$ | — | $\mathrm{m/sec}$ | Specified |
| 2 | Péclet criterion | $\mathrm{Pe}$ | $\mathrm{Pe}=\dfrac{W\cdot 2s}{a^{*}}$ | — | Thermophysical characteristics of air are taken at $t_{\mathrm{in}}\,^\circ\mathrm{C}$ |
| 3 | Equivalent coefficient of thermal conductivity of the winding at $t_{\mathrm{allow}}$ | $\lambda_{\mathrm{eqv}}$ | $\lambda_{\mathrm{eqv}}=\lambda_0+\delta\cdot t_{\mathrm{allow}}$ | $\mathrm{W}/\mathrm{m}\,^\circ\mathrm{C}$ | |
| 4 | Perimeter of the flow cross-section of 1 meter of slot | $U$ | $U=1+s+1+s$ | $\mathrm{m}$ | Calculation is more convenient for 1 running meter of slot |
| 5 | Heat-transfer coefficient in the winding slots | $\alpha$ | $\mathrm{Nu}=f(\mathrm{Re},\,\mathrm{Pr},\,\mathrm{Gr})$ | $\mathrm{W}/\mathrm{m^2}\,^\circ\mathrm{C}$ | According to [3] or [4], depending on the flow regime |
| 6 | Biot criterion | $\mathrm{Bi}$ | $\mathrm{Bi}=\alpha\cdot 2\delta/\lambda_{\mathrm{eqv}}$ | — | |
| 7 | Root of the transcendental equation | $\mu_1$ | $\mathrm{tg}\,\mu_m=\dfrac{2\mathrm{Bi}\cdot\psi_m}{\mu_m^2-\mathrm{Bi}^2}$ | From Table No. 1 |
Continuation of Table 2
| 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|
| 8 | Complex | $\beta$ | $\beta = 4L_0 a^2/\lambda_{\text{eq}}$ | °C | |
| 9 | Complex | $\gamma$ | $\gamma = 8M a^3/\lambda_{\text{eq}}$ | °C | |
| 10 | Ratio of the vertical to the horizontal shield dimensions | $\eta$ | $\eta = \dfrac{a}{b}$ | Fig. 1 | |
| 11 | Coefficient in formulas (5)—(8) | $A_1$ | — | °C | From the nomograms of Fig. 2, according to the values $B_1$, $\beta$, $\gamma$, $\eta$ |
| 12 | Maximum temperature rise at the top of the shield from (5)—(8) | $t_{\max}$ | Analytically or graphically | °C | |
| 13 | Compare $t_{\max}$ and $t_{\text{allow}}$ | There should be agreement, i.e., $t_{\max} \simeq t_{\text{allow}}$ | If $t_{\max}$ and $t_{\text{allow}}$ do not agree, another value of the air velocity $W$ is assigned and the calculation is repeated | ||
| 14 | Total amount of air required for cooling the winding | $Q'$ | $Q' = W \cdot \displaystyle\sum_i S_i \cdot 3600$ | m³/hour | The value $Q'$ is required for selecting the fan of the betatron cooling system |
technical calculation. The latter gives the geometric dimensions and a number of electrical parameters that are necessary for a quantitative assessment of the heat distribution in the vertical rows of the winding busbars by the method of eddy-field modeling [2].
It is convenient to carry out the thermal calculation in the form of Table 2, entering in the first part all the data necessary for the calculation. Ultimately, the air velocity in the cooling ducts of the winding is calculated, at which the maximum temperature on the winding surface does not exceed the permissible value. From the air velocity and the total cross-sectional area of all cooling ducts of the upper and lower windings of the betatron, the total quantity of air required for cooling the winding is calculated.
REFERENCES
-
V. V. Ivanov, G. F. Shilin. Thermal calculation of the magnetizing winding of a betatron with air cooling. Izv. vuzov—Elektromekhanika, No. 8, 1964.
-
S. I. Lur’e. Mathematical modeling of stray magnetic fields of transformers and reactors on electrically conducting paper. Elektrichestvo, No. 10, 1965.
-
F. M. Tarasov. Thin-Layer Heat-Exchange Apparatus. Mashgiz, 1964.
-
S. S. Kutateladze, V. M. Borishanskii. Handbook of Heat Transfer. Gosenergoizdat, 1959.
-
Electrical Engineering Handbook, Vol. 1. Gosenergoizdat, 1962.